Main Dam
Roller Compacted
Concrete (RCC)
Gravity dam (Vol = 1,000,000m3)
Crest length -
492.5m
Dam crest
elevation - 185.0masl
Maximum dam height
- 108m
Dam crest width -
7m
Reservoir
Full Supply Level
(FSL) - 183.0masl
Reservoir Area at
FSL - 444km2
Storage Volume at
FSL - 12.57 x 109m3
Minimum Operating
Level - 168.0masl
Active Storage -
7.72 x 109m3 |
Spillway
Five gated
structure
Designed for
one (1) in a 10,000 year flood of 10,450m3/s
Weir crest
elevation - 166.5masl
Power House
Unit Type - 3
Francis Turbines/Generators of 133MW each
Guaranteed
Peak Efficiency >94%
Installed
Capacity - 400MW
Net Average
long term energy production - 969GWh/yr
|
|
Transmission System
Power produced will be transmitted through extensions to the 161 kV
National Interconnected Transmission System. These extension
facilities to be constructed are:
Bui
Switchyard
Bui –
Teselima Two (2) lines - 18km each
Bui –
Sunyani transmission line - 138km
Bui –
Kintampo transmission line - 70km
*Kintampo
Substation, by GRIDCo |